[1] 郭丽娜,刘均英,彭万忠,等. 动脉置管监测血压在面部整形美容局麻手术中的应用[J].中国美容医学,2021,(4):98-101.
 GUO Li-na,LIU Jun-ying,PENG Wan-zhong,et al. Application of Arterial Catheter Monitoring Blood Pressure in Patients with FacialPlastic Surgery Under Local Anesthesia[J].Medical Aesthetics and Beauty,2021,(4):98-101.
点击复制
 动脉置管监测血压在面部整形美容局麻手术中的应用
()
《中国美容医学》[ISSN:1008-6445/CN:61-1347/R]
- 卷:
-
- 期数:
-
2021年4期
- 页码:
-
98-101
- 栏目:
-
- 出版日期:
-
2021-04-10
文章信息/Info
- Title:
-
 Application of Arterial Catheter Monitoring Blood Pressure in Patients with Facial
Plastic Surgery Under Local Anesthesia
- 文章编号:
-
1008-6455(2021)04-0098-03
- 作者:
-
 郭丽娜1; 刘均英2; 彭万忠2; 姜 洋2; 王爱丽2; 郭学敏2
-
- Author(s):
-
 GUO Li-na1; LIU Jun-ying2; PENG Wan-zhong2; JIANG Yang2; WANG Ai-li2; GUO Xue-min2
-
-
- 关键词:
-
 [关键词]动脉置管; 血压监测; 面部整形美容; 局部麻醉
- Keywords:
-
 Key words: arterial catheter; blood pressure monitoring; facial plastic surgery; local anesthesia
- 分类号:
-
R622
- 文献标志码:
-
A
- 摘要:
-
[摘要]目的:探讨动脉置管监测血压在面部整形美容局麻手术中的应用价值。方法:2016年11月-2019年3月选择在笔者医院
进行面部整形美容局麻手术患者78例,根据随机数字表法分为观察组与对照组各39例。所有患者都给予局麻手术,对照组
给予袖带法监测血压;观察组给予动脉置管监测血压,同时在术中15min也给予了袖带法测量血压。记录两组监测血压的效
果。结果:两组患者术前即刻、术中15min与术后即刻的收缩压、舒张压在组内与组间比较差异都无统计学意义(P >0.05)。
在观察组中,动脉置管与袖带法监测血压的误差都在±5.0mmHg,属于可信区间误差范围内。观察组术后3d的疼痛分级与对
照组比较差异无统计学意义(P >0.05)。对照组在血压监测中未出现任何并发症,观察组出现1例血肿与1例感染,发生率为
5.1%,组间比较差异无统计学意义(P >0.05)。结论:动脉置管监测血压在面部整形美容局麻手术中的应用依然具有很好的
可靠性与安全性,能追踪围手术期血压的变化,为保障患者的手术安全提供参考。
- Abstract:
-
Abstract: Objective To investigate the values of arterial catheter monitoring of blood pressure in patients with facial plastic
surgery under local anesthesia. Methods From November 2016 to March 2019, 78 patients with facial plastic surgery and local
anesthesia were selected from our hospital and were equally divided into the observation group and the control group accorded
to the random number table method. All patients were given local anesthesia, the control group were given cuff method to
monitor blood pressure; the observation group were given arterial catheter to monitor blood pressure, and the cuff method were
also used to measure blood pressure at intraoperative 15 minutes. The effects of monitoring blood pressure were recorded in
both groups. Results There were no significant differences in the systolic and diastolic blood pressure between the two groups
immediately before surgery, 1intraoperative 15 minutes, and immediately after surgery (P >0.05). In the observation group,
the error of monitoring the blood pressure by the arterial catheter and the cuff method were between ±5.0mmHg, which were
within the range of the confidence interval error. There were no significant difference in the pain grading compared between the
observation group and the control group at 3 days after operation (P >0.05). There were no complication in the blood pressure
monitoring in the control group. There were one patient of hematoma and one patient of infection in the observation group, the
incidence rates were 5.1%, and there were no significant difference compared between the two groups (P >0.05). Conclusion
The application of arterial catheter monitoring blood pressure in patients with facial plastic surgery and local anesthesia is still
very reliable and safe. It can track the perioperative blood pressure and provide reference for the safety of patients.
更新日期/Last Update:
2021-05-11