[1]沈 琳,彭国光,吴美珍.不同印模方式在种植磨牙单冠中的应用比较?/html>[J].中国美容医学,2021,(11):128-130.
 SHEN Lin,PENG Guo-guang,WU Mei-zhen.Comparison of Restoration Effects between 3Shape Trios and Impression of Silicon Rubber for Implant Restoration of Molars?/html>[J].Medical Aesthetics and Beauty,2021,(11):128-130.
点击复制

不同印模方式在种植磨牙单冠中的应用比较?/html>()
分享到:

《中国美容医学》[ISSN:1008-6445/CN:61-1347/R]

卷:
期数:
2021年11期
页码:
128-130
栏目:
出版日期:
2021-11-10

文章信息/Info

Title:
Comparison of Restoration Effects between 3Shape Trios and Impression of Silicon Rubber for Implant Restoration of Molars?/html>
文章编号:
1008-6455(2021)11-0128-03
作者:
沈 琳彭国光吴美珍
Author(s):
SHEN LinPENG Guo-guangWU Mei-zhen
关键词:
[关键词]3Shape Trios种植单冠硅橡胶印模技术口内扫描全瓷冠
Keywords:
Key words: 3Shape Trios implant molar restoration impression of silicon rubber intraoral scan all-ceramic crown
分类号:
R782.12
文献标志码:
A
摘要:
[摘要]目的:比较使用口内扫描法和传统硅橡胶法制取种植磨牙单冠的临床修复效果评价。方法:选择62例患者(共86颗 后牙),随机分为试验组和对照组,每组43颗牙(其中前磨牙13颗,磨牙30颗)。临床分别采用硅橡胶法和口内扫描法制 取印模,制作氧化锆全瓷修复体,于治疗后2周复诊,采用VAS评分量表及改良的美国公共卫生总署(United states public health service,USPHS)评价系统对修复效果及舒适度进行评价。结果:口内扫描法组的患者满意度更高,舒适度更好,两组 USPHS评分中除口内扫描组修复体的边缘适合性A级比例比对照组高外,其余指标的A级比例差异无统计学意义(P>0.05)。结 论:口内扫描技术应用在种植磨牙单冠的印模制作中,修复效果良好、精度高外,患者满意度高,值得临床推广应用。
Abstract:
Abstract: Objective To compare the difference of restoration effects between digital intraoral scanning technology and conventional impression of silicon rubber for implant restoration of the posterior teeth.Methods In this study,62 patients undergoing implant restorations for the posterior teeth were enrolled.43 patients accepted 3Shape intraoral scan to get digital impressions(direct group),while 43 patients were treated by conventional impression technology(control group).A satisfaction survey and VAS value scale was conducted after treatment for 2 weeks.The check and evaluation were conducted according to the adapted USPHS standards after treatment.Results The patients in the oral scanning group were more satisfi ed and more comfortable. In the USPHS score of the two groups, except for the A-level ratio of marginal fi tness of the prosthesis in the oral scanning group was higher than that in the control group, there was no signifi cant diff erence in the A-level ratio of other indicators (P>0.05). Conclusion The application of intraoral scanning technology in the preparation of implant restoration has good repairing eff ect,high precision and high patient satisfaction.It is worth popularizing in clinic.

相似文献/References:

[1]赵许兵,陈 诚,姚天华,等. 3Shape Trios口内扫描仪在E.max铸瓷高嵌体临床应用中的效果评价[J].中国美容医学,2018,(11):93.
 ZHAO Xu-bing,CHEN Cheng,YAO Tian-hua,et al. Clinical Effect Evaluation of E-Max Cast Porcelain Onlays Restoration Fabricated By 3Shape Trios System[J].Medical Aesthetics and Beauty,2018,(11):93.

更新日期/Last Update: 2021-12-02