[1]廖阳阳,向绍雯,谢成婕.Er,Cr:YSGG激光与传统手术治疗牙龈瘤的舒适化疗效比较[J].中国美容医学,2022,(7):96-99.
 LIAO Yangyang,XIANG Shaowen,XIE Chengjie.Comparison of Comfort Effect Between Er,Cr:YSGG Laser and Conventional Scalpel in Epulis Treatment[J].Medical Aesthetics and Beauty,2022,(7):96-99.
点击复制

Er,Cr:YSGG激光与传统手术治疗牙龈瘤的舒适化疗效比较()
分享到:

《中国美容医学》[ISSN:1008-6445/CN:61-1347/R]

卷:
期数:
2022年7期
页码:
96-99
栏目:
出版日期:
2022-07-10

文章信息/Info

Title:
Comparison of Comfort Effect Between Er,Cr:YSGG Laser and Conventional Scalpel in Epulis Treatment
文章编号:
1008-6455(2022)07-0096-04
作者:
廖阳阳向绍雯谢成婕
(南方医科大学口腔医院 广东省口腔医院 海珠广场院区牙周病科 广东 广州 510280 )
Author(s):
LIAO YangyangXIANG Shaowen XIE Chengjie
(Department of Periodontology,Faculty of Haizhu Square, Stomatological Hospital,Southern Medical University,Guangzhou 510280, Guangdong,China)
关键词:
ErCr:YSGG激光牙龈瘤切除舒适化疗效牙科焦虑症
Keywords:
ErCr:YSGG laser epulis resection comfort effect dental anxiety
分类号:
R139.81
文献标志码:
A
摘要:
目的:比较Er,Cr:YSGG激光及传统手术方法切除牙龈瘤的舒适化疗效。方法:选取2016年1月-2019年12月南方医科大学口腔医院牙周科就诊的74例牙龈瘤患者资料进行回顾性分析,随机进行分组,包括传统手术组和激光切除组,每组37例。术前以Corach’s牙科焦虑量表(Corach’s dental anxiety scale,DAS)和牙科畏惧量表(Dental fear scale, DFS)进行牙科焦虑状况评分;两组患者于术后当天、1、3、5、7 d进行视觉模拟评分(Visual analog scale,VAS)记录疼痛值,同时记录术后临床表现评价表,术后6~12个月回访观察复发情况评判牙龈瘤治疗效果。结果:激光切除组DAS、DFS值显著低于传统手术组,激光切除组术后VAS评分均显著下降。传统手术组术后仅3、5、7 d VAS值差异有统计学意义,并呈逐渐下降趋势。激光切除组术后除第7天外,VAS值均低于传统手术组。焦虑值与VAS相关分析显示激光切除组DAS及DFS焦虑值与术后当天、1 d及3 d的VAS显著相关。传统手术组DAS及DFS焦虑值与术后各时段VAS均显著相关。激光切除组患者术后当天、1 d肿胀及出血程度显著低于传统手术组。6~12个月回访,两组患者均未见复发。结论:Er,Cr:YSGG激光治疗牙龈瘤较传统手 术可引起更少牙科焦虑,能提高患者术中舒适度,减少术后疼痛,且具有术后反应轻微和复发率低的特点。
Abstract:
Objective To compare the comfort dentistry effect of Er,Cr:YSGG laser and conventional scalpel in treating epulis resection. Methods A total number of 74 epulis patients underwent epulis resection with either Er,Cr:YSGG laser or conventional scalpel in Stomatological Hospital, Southern Medical University from January 2016 to December 2019 were included in this retrospective study. There were 37 patients in Er,Cr:YSGG laser group while 37 patients in conventional scalpel group. Pre-operation Corach’s Dental Anxiety Scale (DAS) and Dental Fear Scale (DFS) were recorded. Post-operative Visual analog scale (VAS) at day 0,day 1,day 3,day 5 and day 7 was recorded.Post-operative manifestation was recorded including swelling,bleeding, nausea and breath. Post-operative epulis treatment effect evaluation was at 6-12 months after the surgery. Results DAS, DFS and VAS were significantly decreased in Er,Cr:YSGG laser group (P <0.05). In conventional scalpel group, VAS was significantly decreased in day 3, day 5 and day 7 (P<0.05). Compared to conventional scalpel group, VAS was significantly decreased except day 7 in Er,Cr:YSGG laser group (P <0.05). In the correlation study, significance of VAS with DAS and DFS was shown on day 0,day 1,day 3 in both groups, and day 5, day 7 in conventional scalpel group. But the significance was not shown on day 5 and day 7 in Er,Cr:YSGG laser group.Er,Cr:YSGG laser group presented less swelling and bleeding at day 0 and day 1 post-operation. There was no recurrence in both groups after 6-12months. Conclusion Er,Cr:YSGG laser can cause less dental fear and pain feeling in epulis treatment, while the post-operation manifestation and prognosis are also better. In this case, Er,Cr:YSGG laser is propitious to comfort dentistry in clinical utilization.

相似文献/References:

[1]肖海鹰,魏 威,李卓俊. Er,Cr:YSGG激光牙体预备在IPS Empress铸瓷贴面修复前牙中的应用[J].中国美容医学,2018,(08):98.
 XIAO Hai-ying,WEI Wei,LI Zhuo-jun. The Application of Er,Cr:YSGG Laser Tooth Preparation in the Anterior Teeth of IPS Empress Casting Porcelain Veneer[J].Medical Aesthetics and Beauty,2018,(7):98.

更新日期/Last Update: 2022-07-26