[1]钟 香,柳志文. Geramage聚合瓷贴面修复体用于活髓前牙美容对牙周相关指标的影响[J].中国美容医学,2018,(03):83-86.
 ZHONG Xiang,LIU Zhi-wen. Effects of Geramage Polymeric Porcelain Veneer Restoration on Periodontal Correlation Indexes of Live Pulp front Teeth Whitening[J].Medical Aesthetics and Beauty,2018,(03):83-86.
点击复制

 Geramage聚合瓷贴面修复体用于活髓前牙美容对牙周相关指标的影响()
分享到:

《中国美容医学》[ISSN:1008-6445/CN:61-1347/R]

卷:
期数:
2018年03期
页码:
83-86
栏目:
出版日期:
2018-04-10

文章信息/Info

Title:
 Effects of Geramage Polymeric Porcelain Veneer Restoration on Periodontal Correlation Indexes of Live Pulp front Teeth Whitening
文章编号:
1008-6455(2018)03-0083-04
作者:
 钟 香柳志文
Author(s):
 ZHONG XiangLIU Zhi-wen
关键词:
 [关键词]Geramage聚合瓷贴面修复体活髓前牙牙周美容修复
Keywords:
 Key words: Geramage polymeric porcelain veneer restoration live pulp front teeth periodontal beauty repair
分类号:
R783.4
文献标志码:
A
摘要:
[摘要]目的:对比间接法Geramage聚合瓷贴面修复体和直接法光固化树脂贴面修复对牙周相关指标的影响。方法:选取82例
(共222颗患牙)行活髓前牙美容的患者,按随机数表法分为观察组41例(共118颗患牙)与对照组41例(共104颗患牙)。观察
组采取间接法Geramage聚合瓷贴面修复,对照组采取直接法光固化树脂贴面修复。比较两组修复1年后的修复体完整度、边
缘染色、与邻牙颜色匹配度、边缘适合性、牙髓状态及基牙敏感程度,菌斑指数(PI)、牙龈指数(GI)、龈沟探诊深度(PD)、
龈沟液量(GCF)、龈沟液中白介素-1α(IL-1α)浓度。结果:两组患者修复后1年,修复体完整度、牙髓状态及基牙敏感程度
的成功率比较,差异无统计学意义(P >0.05)。观察组边缘染色、与邻牙颜色匹配度、边缘适合性的成功率分别为97.46%、
98.31%、97.46%,显著高于对照组91.35%、90.38%、89.42%,有统计学意义(P <0.05)。观察组修复牙的PI、GI评分、GCF
与IL-1α分别为(1.30±0.57)分、(0.09±0.11)分、(1.87±0.57)mg、(69.32±8.17)ng/ml,显著低于对照组(1.48±0.6)
分、(0.32±0.14)、(2.35±0.69)mg、(75.03±7.65)ng/ml(P<0.05)。结论:间接法Geramage聚合瓷贴面修复可较好地再
现天然牙形态,表面光滑,色泽稳定,与邻牙颜色匹配、边缘适合性好,且不易发生边缘微渗透,可避免边缘染色与菌斑堆
积,对牙龈及牙周组织的健康更为有利。

Abstract:

Abstract: Objective To compare the influence of indirect method Geramage polymeric porcelain veneer restoration and direct
method light curing resin veneer restorationon periodontal related index. Methods A toatl of 82 patients (a total of 222 teeth)
for prescription of the live pulp front teeth were selected, and divided into observation group (41 patients, 118 teeth) and control
group (41 patients, 104 teeth) according to random number table method. The observation group was treated with indirect
method Geramage polymeric porcelain veneer restoration, and the control group was treated with direct method light curing
resin veneer restoration. The integrity, edge coloring, color matching with neighboring teeth, edge suitability, dental pulp state
and abutment sensitivity of restorations, the plaque index (PI), gingival index (GI),depth of gingival sagittal (PD), gingival
crevicular fluid volume (GCF), interleukin-1α (IL-1α) in gingival crevicular fluid at 1 year after repair were compared between
two groups. Results There were no significant difference in the success rate of the integrity, dental pulp state and abutment
sensitivity of restorations at 1 year after repair in two groups (P >0.05). The success rate of edge coloring, color matching
with neighboring teeth, edge suitability were 97.46%, 98.31% and 97.46%, respectively, which were significantly higher than
91.35%, 90.38%, 89.42% in the control group (P <0.05).The score of PI, GI and the levels of GCF and IL-1α were (1.30±0.5
7),(0.09±0.11),(1.87±0.57) mg, (69.32±8.17) ng/ml, which were significantly lower than (1.48±0.6), (0.32±0.14), (2.35±0.69)mg,
(75.03±7.65) ng/ml in control group (P <0.05). Conclusion The indirect method Geramage polymeric porcelain veneer
restoration can better reproduce natural tooth shape,smooth surface, color and stability, with the adjacent tooth color match,the
edge of a good fit. And less prone to edge micro-infiltration, to avoid edge staining and plaque accumulation,the gums and
periodontal tissue health was more favorable.

相似文献/References:

[1]. 埋线美容专栏[J].中国美容医学,2018,(01):0.
 [J].Medical Aesthetics and Beauty,2018,(03):0.
[2]杨 震. 应用透明质酸颏部填充联合A型肉毒毒素咬肌注射重塑面部下1/3轮廓的效果观察[J].中国美容医学,2018,(03):1.
 YANG Zhen. Effect of Hyaluronic Acid Chin Filling Combined with Botulinum Toxin Type A Masseter Muscle Injection to Reconstruct the Facial Contour of the Lower 1/3[J].Medical Aesthetics and Beauty,2018,(03):1.
[3]祝闽辉,张栋梁,叶祥柏,等. 皮肤软组织扩张术埋置注液期并发症危险因素研究[J].中国美容医学,2018,(03):4.
 ZHU Min-hui,ZHANG Dong-liang,YE Xiang-bo,et al. Risk Factors of Complications after Tissue Expasion[J].Medical Aesthetics and Beauty,2018,(03):4.
[4]刘申松,杨永成. 自体脂肪颗粒移植联合假体隆乳术在哺乳后乳腺萎缩整形术中的应用[J].中国美容医学,2018,(03):9.
 LIU Shen-song,YANG Yong-cheng. Application of Autologous Fat Granule Graft Combined with Prosthesis Combined Augmentation Mammoplasty in Breast Reconstruction of Breast Atrophy Patients after Breast-feeding[J].Medical Aesthetics and Beauty,2018,(03):9.
[5]韩 星,胡守舵,陈晓芳,等.自体脂肪颗粒移植促进手部年轻化的临床观察[J].中国美容医学,2018,(03):12.
 HAN Xing,HU Shou-duo,CHEN Xiao-fang,et al. The Effect of Autologous Fat Grafting in Hand Rejuvenation[J].Medical Aesthetics and Beauty,2018,(03):12.
[6]李胜旭,苏映军,杨 宽,等. 封闭负压引流技术在先天性并指分指植皮术中的应用[J].中国美容医学,2018,(03):15.
 LI Sheng-xu,SU Ying-jun,YANG Kuan,et al. Application of Vacuum Sealing Drainage for Skin Graft in Patients with Congenital Syndactyly of the Hand[J].Medical Aesthetics and Beauty,2018,(03):15.
[7]陈 波,路 会,马 力,等. 钝针皮下层扇形注射透明质酸矫正面颊部凹陷[J].中国美容医学,2018,(03):18.
 CHEN Bo,LU Hui,MA Li,et al. Correction of Cheek Depression by Fanshaped Hyaluronic Acid Injection in Subcutaneous Layers with Blunt Needle[J].Medical Aesthetics and Beauty,2018,(03):18.
[8]曾德斌,栗鹏程,邱勋永,等. 不同超薄游离穿支皮瓣修复手部软组织缺损效果比较[J].中国美容医学,2018,(03):21.
 ZENG De-bin,LI Peng-cheng,QIU Xun-yong,et al. Comparison on the Repair Effect of Different Ultrathin Free Perforator Flaps in the Treatment of Patients with Soft Tissue Defect of Hand[J].Medical Aesthetics and Beauty,2018,(03):21.
[9]程 定,崔树英,郑 乐,等. 改道引流联合VSD技术修复会阴部撕裂伤的临床研究[J].中国美容医学,2018,(03):24.
 CHENG Ding,CUI Shu-ying,ZHENG Le,et al. Clinical Study on Diverted Drainage Combined with Vacuum Sealing Drainage Technique to Repair the Laceration of the Perineum[J].Medical Aesthetics and Beauty,2018,(03):24.
[10]李云峰,吴泽勇,黄海华,等. 全厚皮片游离移植矫治儿童足背瘢痕挛缩畸形[J].中国美容医学,2018,(03):27.
 LI Yun-feng,WU Ze-yong,HUANG Hai-hua,et al. Full-thickness Skin Graft for the Treatment of Cicatricial Contracture of the Dorsum of Foot in Children[J].Medical Aesthetics and Beauty,2018,(03):27.
[11]刘冰锋. Geramage聚合瓷修复体在活髓前牙美容修复中的应用[J].中国美容医学,2018,(05):91.
 LIU Bing-feng. Application of Geramage Polymerization Porcelain Restorations in Esthetic Restoration of Vital Incisors[J].Medical Aesthetics and Beauty,2018,(03):91.

更新日期/Last Update: 2018-06-07