[1]温裕庆,李荣兴,钟 毅,等. 挛缩性瘢痕松解术联合自制负压引流装置的应用探讨[J].中国美容医学,2018,(12):40-43.
 WEN Yu-qing,LI Rong-xing,ZHONG Yi,et al. Application of Contracture Scar Release Combined with Self-made Negative Pressure Drainage Device[J].Medical Aesthetics and Beauty,2018,(12):40-43.
点击复制

 挛缩性瘢痕松解术联合自制负压引流装置的应用探讨
()
分享到:

《中国美容医学》[ISSN:1008-6445/CN:61-1347/R]

卷:
期数:
2018年12期
页码:
40-43
栏目:
出版日期:
2018-12-20

文章信息/Info

Title:
 Application of Contracture Scar Release Combined with Self-made Negative Pressure Drainage Device
文章编号:
1008-6455(2018)12-0040-04
作者:
温裕庆李荣兴钟 毅林 宙傅丽琴
Author(s):
WEN Yu-qingLI Rong-xingZHONG YiLIN ZhouFU Li-qin
关键词:
[关键词]挛缩性瘢痕松解术Z成形术自制负压引流装置皮缘坏死愈合质量
Keywords:
Key words: contracture scar release operation Z-plasty self-made negative pressure drainage device skin edge necrosishealing quality
分类号:
R622
文献标志码:
A
摘要:

[摘要]目的:探讨挛缩性瘢痕松解术联合自制负压引流装置的疗效。方法:选取笔者医院2016年1月-2018年10月收治的35例
挛缩性瘢痕患者为治疗组,行挛缩性瘢痕松解+Z成形,随后予自制负压引流装置,另选取2013年1月-2015年12月收治的35例
挛缩性瘢痕患者为对照组,缩性瘢痕松解+Z成形后仅予无菌敷料包扎。两组患者均连续观察21d,比较其瘢痕边缘坏死与创面
感染的发生情况、换药疼痛程度、功能评价、创面愈合时间及住院时间等。结果:治疗组并发症发生率为5.7%低于对照组的
14.3%,差异有统计学意义(P <0.05)。治疗组治疗后前4次换药疼痛评分均低于对照组,差异有统计学意义(P <0.05)。
治疗组的功能评价总有效率为94.3%高于对照组的71.4%,差异有统计学意义(P <0.05)。治疗组的创面愈合时间与住院时
间均少于对照组,差异有统计学意义(P <0.05)。结论:挛缩性瘢痕松解术联合自制负压引流装置能使瘢痕瓣更好成活,
减少皮缘坏死,提高愈合质量,更符合瘢痕防治动态综合疗法。
Abstract:
Abstract: Objective To investigate the efficacy of contracture scar release combined with self-made negative pressure drainage
device. Methods Thirty-five patients with contracture scars admitted to our hospital from January 2016 to October 2018 were
selected as the study subjects. The patients in the treatment group were treated with Z-plasty and vacuum drainage device.
Another 35 patients with contracture scars admitted to our hospital from January 2013 to December 2015 were selected as
the control subjects. The control group was treated with sterile dressing. The incidence of scar marginal necrosis and wound
infection, dressing change pain, functional evaluation, wound healing time, hospitalization time and hospitalization cost were
compared between the two groups. Results The incidence of complications in the treatment group was 5.7% lower than that in
the control group (14.3%), the difference was statistically significant(P <0.05). After treatment, the pain score of the treatment
group was lower than that of the control group(P <0.05). The total effective rate of functional evaluation in the treatment
group was 94.3% higher than that in the control group(71.4%, P <0.05). The wound healing time and hospitalization time in
the treatment group were less than those in the control group(P <0.05). Conclusion Contracture scar lysis combined with
self-made negative pressure drainage device can make the scar flap survive better, reduce skin necrosis, improve the quality of
healing, more in line with the dynamic comprehensive therapy of scar prevention and treatment.
更新日期/Last Update: 2019-01-08